01

Why the nameplate number is not the whole story

Every cooling capacity figure published for a split system is measured under a set of standard conditions, and those conditions are gentler than a real afternoon in a hot market. As the outdoor temperature climbs, the gap between the indoor and outdoor side grows, the compressor works against a higher pressure, and the useful cooling that reaches the room falls below the nominal number. Two units with the same nominal capacity can therefore behave differently once the ambient passes the point where the rating was taken. This is why a sizing decision made from a catalogue printed for a temperate country often ends in a unit that runs all day and still cannot hold the set point. The correction that applies at a given ambient is confirmed with the quotation, because it depends on the platform and the test standard behind the figure.

02

The factors that actually change the load

Cooling load is driven by more than the square metres of a room. Ceiling height and total volume matter, because hot air rises and a tall room holds more heat. The area and orientation of glass decide how much solar gain enters, and an unshaded west wall or a single-glazed window can add as much load as several more square metres of floor. Roof construction and insulation decide how much heat comes down from above, which is a large factor in single-storey buildings in hot regions. Occupancy and internal equipment add again, particularly in shops, restaurants and offices where people gather and appliances run. When a distributor quotes capacities to dealers, these factors explain why the same room size can need different units in different buildings, and why a simple rule of thumb should be a starting point rather than the answer.

03

The cost of sizing too small

An undersized unit never rests. It runs at full output for most of the day, fails to reach the set temperature during the hottest hours, and gives the customer the impression that the brand is weak rather than that the size was wrong. That constant running shortens compressor life, raises the electricity bill the customer sees, and produces the complaints that a distributor has to answer in the first season. In a hot market the failure is most visible exactly when it matters, at the peak of the afternoon, and no amount of service work fixes a unit that was never big enough. A smaller unit can be the right choice for a small, shaded room with low occupancy, but the decision should follow the calculated load in the local climate, not the price tier alone.

04

The cost of sizing too large

Oversizing has its own costs, and they are easy to underestimate. A unit that is too large reaches the set point quickly and then cycles on and off, so it removes less moisture and can leave a room feeling cold and clammy at the same time. Short cycles are harder on the compressor than steady running, they make the noise of start-up more frequent, and they waste the extra capacity the customer paid for. The buyer also pays more upfront for a unit that will not be used to its full output. The aim is not the biggest unit available but the one that holds the room at the target temperature on the hottest day the market experiences, with a sensible margin for the days that exceed the average.

05

How to size a range rather than a single room

An importer does not size one room, they size a programme. The practical approach is to work out the capacities that cover the common rooms in the market, then check how many models that produces and whether the mix fits the container and the price ladder. In many hot markets a small number of capacity steps covers most residential demand, and the distributor sells up when the room is large, sun-facing or heavily occupied. Building the range this way keeps the stock simple, gives the dealer a clear story, and avoids carrying slow-moving sizes. The capacity steps available, the models that carry them and the mix that loads well together are confirmed with the quotation and the order.

06

What to confirm with the quotation

Before committing, confirm the nominal capacity steps you intend to sell, the conditions behind those figures and any correction data that applies to high ambient temperatures. Confirm the power supply the models expect, the refrigerant they use and the documentation that ships with them, and ask how the range behaves at the peak temperature of your market. Confirm the loading plan for a mixed container so that the capacities you have chosen travel together efficiently. Where a figure is not yet verified for the model or the market, it stays open and is written as confirmed with the quotation. Our market pages describe the climate and the sizing priorities we track for each destination, and our Shinco model list shows how the series sit together.